PE ACP panel ban's impact on construction industry

Monday, August 20th, 2018Construction, NewsMadeleine Swain

Following the recent announcement by the NSW Fair Trading’s Commissioner, Rose Webb, prohibiting the use of some types of combustible aluminium composite panels (ACPs) on certain building types, Fairview, which runs the SafeClad training programs, has released a response detailing the ban's impact on the construction industry.

Fairview believes the ban is a well-reasoned and good initiative by the NSW Government with a view to ensuring safer buildings and restoring public and industry confidence. Fairview fully supports this ban.

What states and territories does this ban apply to?

This ban applies in NSW only and has some differences to the restrictions/bans imposed by other Australian regulators, namely Victoria, Tasmania and South Australia.

The Fairview technical team has reviewed the notice issued by Fair Trading and share below their summary and views of what this means for the construction industry in NSW and for ACP products in general.

What products does this ban apply to?

The NSW ban applies specifically to Aluminium Composite Panels (ACPs) with a core comprising  greater than 30 percent polyethylene (PE) by mass. They are prohibited from use on any external wall, cladding, façade etc on building types A & B (as defined in the Building Code of Australia).

Are there any exemptions from the ban?

Yes, there are two exemptions from this ban:

  1. the building product is not deemed combustible (non-combustible) when tested to AS1530.1, or
  2. the building product achieves a complete pass tested to the recently introduced AS5113 large scale fire propagation and classification test for external walls of buildings (note: the wall and cladding must be constructed and installed in a manner identical to the tested prototype).

Additionally, testing of the above has to be completed on or after 1 July 2017, and by a NATA approved lab.

So which ACPs are exempt from this ban?

This ban does not apply to products that:

  1. contain 30 percent or less combustible polyethylene
  2. are not deemed combustible when tested to AS1530.1 (by NATA approved lab after 1/7/17), and
  3. when installed on and become part of an external wall assembly (full wall build-up) that, when tested, successfully pass all classifications in accordance with AS5113 (by a NATA approved lab after 1/7/17).

If my ACP is not affected by this ban, is it compliant?

No, a product exempted or not affected by this ban is not automatically deemed compliant. These products must still demonstrate compliance with the Building Code of Australia (BCA).

Note: most solid core ACPs contain combustible content in the core. Even if this is less than 30 percent it is likely they do not comply for use on type A & B buildings when tested in accordance with the BCA.

When does the ban take effect?

This building product use ban commenced on Wednesday 15 August 2018 and remains in force until it is revoked.

Why was the ban introduced?

Fair Trading has based its decision to implement the building product use ban on the following reasons:

  • PE core ACPs on type A & B construction pose a high fire safety risk due to combustibility.
  • In particular, ACPs with more than 30 percent PE core products pose a safety risk that contravenes the BCA.
  • The National Code of Construction is not currently sufficient to address these safety risks.

What does this mean for Vitrabond FR and its competitors?

Most reputable ACPs such as Vitrabond FR contain 30 percent or less PE (combustible content) in the core. This means that these products are not banned; however, it also does not mean that they are compliant. These products still require stringent testing to demonstrate compliance or otherwise in accordance with the BCA.

Vitrabond's FR core has been independently tested by the CSIRO to confirm the percentage of PE. The CSIRO report confirms that the Vitrabond FR core contains 24.5 percent PE. Vitrabond FR is therefore not affected by this ban.

image: RF123's Georgy Dzyura © RF123.com





Leave a Reply Cancel Reply

Your email address will not be published.


Comment


Name

Email

Url


Recent Posts

  • Coles and partners Replas, Red Group and RMIT install largest Polyrok pour
  • Common discrimination and no support – the plight of women in construction
  • New tech to make construction at heights safer
  • Construction is about using the right tools for the job and business software is no different
  • New app helps tradies and sole traders stay on top of their finances
Load More...Follow on Instagram








©2019 Niche Media. All Rights Reserved. Terms & Conditions| Privacy Policy

This website uses cookies to provide you with the best browsing experience.

Find out more or adjust your settings.

Better Building Daily
Powered by GDPR plugin
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.